MIL-PRF-62218B
TABLE II. Classification of inspections.
First
Conformance
Title
Requirement
Inspection article
Examination Control
Materials
3.2 thru
4.6.1
X
3.2.1.2
Halogenated
3.2.1.2
4.6.4
X
hydrocarbons
Defects (see table I)
3.3.6, 3.5, and
4.6.3
X
X
5.1
Nonvolatile contents
3.3.1
4.6.5
X
Water content
3.3.2
4.6.5
X
Lead content
3.3.3
4.6.5
X
Flash point
3.3.4
4.6.5
X
Condition in container
3.3.5
4.6.5.1
X
Film characteristics
3.4.1
4.6.6
X
X
Creep
3.4.2
4.6.7
X
X
Copper corrosion
3.4.3
4.6.8
X
Detergent resistance
3.4.5
4.6.10
X
X
Chip resistance
3.4.6
4.6.11
X
X
Solvent vapor wash
3.4.7
4.6.12
X
X
resistance
Condition to touch
3.4.8
4.6.13
X
X
Low temperature stability
3.4.9.1
4.6.14.1
X
X
Low temperature
3.4.9.2
4.6.14.2
X
X
sprayability
Low temperature
3.4.9.3
4.6.14.3
X
X
flexibility
High temperature
3.4.9.4
4.6.14.4
X
X
sprayability
High temperature flow
3.4.9.5
4.6.14.5
X
X
resistance
Salt fog
3.4.9.6
X
Salt water immersion
3.4.9.7
4.6.14.6
X
Cyclic environmental
3.4.9.8
X
conditions
4.3 Conformance inspection.
4.3.1 Sampling. Samples from an inspection lot for conformance inspection shall be
selected in accordance with ANSI/ASQC Z1.4. Each sample selected shall be inspected as
specified herein for the defects listed in table I. Conformance to a lot shall be accepted when zero
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.