MIL-C-47244A(MI)
FIGURE 1 Flow test jig.
4.6.5.2 First article hardness test. Curing conditions and hardness values for
first article testing shall be as specified in table I for conditions l and 2.
4.6.5.3 Quality conformance hardness test. Curing conditions and hardness
value for quality conformance testing shall be as specified in table I for condition 3.
4.6.6 Low temperature stability. Two room-temperaure test panels shall be
placed in a temperature chamber for low temperature stability testing. The
temperature shall be lowered to -54° ± 3°C at a rate of 10 per minute. The test panels
shall remain at this temperature for not less than 1 hour, after which they shall be
examined. There shall be no evidence of cracking, checking, or loss of adhesion.