MIL-DTL-85054D(AS)
b. Test samples (see 4.2).
c. A certified statement specifically identifying each ingredient in the compound by
chemical name, source, and percentage by weight.
d. Information on the percent by weight of the propellant used and the composition of the
propellant furnished in type I and IA containers.
e. Instructions for the application of the compound.
f. A Material Safety Data Sheet for the samples being submitted for test (see 6.5).
6.3.3 First article sample and inspection for a subsequent contract. If a contractor has
previously furnished the compound in accordance with the requirements of this specification and
that product has been found to be satisfactory, the requirement for a first article sample and its
submittal for any subsequent contract or order may be waived. Waiver is at the discretion of the
Commander, Naval Air Warfare Center Aircraft Division, AIR 4.3.4.1, 48066 Shaw Rd., Bldg
2188, Patuxent River, MD 20670-1908.
6.4 Conformance inspection information.
6.4.1 Inspection lot. An inspection lot is all the compound produced during a single batch
operation and offered for acceptance at one time.
6.4.2 Certification. The manufacturer at the time of conformance inspection will certify
that there has been no formulation or process change from that which resulted in the production
of the first article inspection sample. Each ingredient material must be identified with the name
of its manufacturer and that manufacturer's trade name and formula number.
6.4.3 Conformance rejection and retest. Failure of any conformance inspection will result
in the rejection of the batch from which it was obtained. Rejected material cannot be resubmitted
for acceptance without written approval from the responsible activity (see 6.3.1). The application
for resubmission will contain all details concerning previous rejections and measures taken to
correct these deficiencies.
6.5 Material Safety Data Sheets. A Material Safety Data Sheet (MSDS) must be prepared
and submitted in accordance with FED-STD-313. Questions pertinent to the effect of this
compound on the health of personnel when used for its intended purpose must be referred by the
procuring activity to the appropriate medical service who will act as adviser to the procuring
activity.
6.6 Test condition waiver. A waiver of the test condition requirement is permitted when
proper conditioning facilities are not available for control testing (see 6.2). However, for referee
purposes, the specified tests must be performed under the specified atmospheric conditions.