MIL-DTL-85054D(AS)
3.5 Self-pressurized containers. Filled self-pressurized containers (see 3.2.3.1) shall meet
the requirements of 3.5.1 through 3.5.3.
3.5.1 Leakage. The self-pressurized containers shall not leak or become distorted when
tested as specified in 4.6.6.1.
3.5.2 Fill. Each self-pressurized container shall contain a minimum of 11 ounces by weight
of the compound, when tested as specified in 4.6.6.2.
3.5.3 Performance of self-pressurized containers. Compounds packaged in self-pressurized
containers shall spray uniformly, adhere to the panel, and shall not foam excessively or sag, when
tested as specified in 4.6.6.3.
3.6 Identification of compound container. Individual containers shall be identified in
accordance with MIL-STD-290 and ANSI Z129.1. The identification shall be legible and unless
otherwise specified in the contract (see 6.2) shall be accomplished by lithographing or silkscreen
process. Paper coated identification labels on self-pressurized containers are not acceptable; any
special marking specified in the contract or order shall also be included (see 6.2). There shall be
front and rear face identification located opposite each other on the container.
3.6.1 Front face identification. The front face identification shall be as follows:
(NSN)
CORROSION PREVENTIVE COMPOUND,
WATER-DISPLACING, TRANSPARENT (Formerly AMLGUARD)
MIL-DTL-85054D(AS) Type ______CLASS ________
Lot ______ Date manufactured ______
VOC content ______
(Contract no.)
(Manufacturer's name)
(Manufacturer's address)
(Manufacturer's product no.)
% by weight of propellant (for aerosol only)
(Net wt) Includes
Important: For best results follow instructions on reverse side of container.